『Refrigerant mass flow meter』Related information(v cone flow meter|rotary gas meter|gallon meter|gear meter|metal tube rotameter|glass tube rotameter|nutating disk meter|transit time ultrasonic flow meter|wedge flow meter|pd meters|hydraulic flow meter|ultrasonic water flow meter|water flow meter|air flow meter|magnetic water flow meter|oxygen flow meter|gas flow meter|argon flow meter|air velocity meter|gasoline flow meter|fuel flow meter|ultrasonic water meter|digital water meter|nitrogen flow meter|solid flow meter|Oxygen tank flow meter|digital water flow meter|diesel fuel flow meter|steam flow meter|02 flow meter|compressed air flow meter|oil flow meter|liquid flow meter)

1. Testing method for air conditioning performance indicators
The testing method for air conditioning performance indicators mainly includes five core steps: clarifying the testing objectives, building the system architecture, arranging liquid and liquid sensors, designing a data acquisition system, and executing the testing process, as follows
1. The testing objectives need to clearly verify the core performance indicators of the air conditioning system, including cooling/heating efficiency (COP value), cooling capacity, and heating capacity; Monitor the dynamic changes in refrigerant quality and flow rate; Optimize the collaborative control logic between the compressor and expansion valve; Analyze the pressure stability of high and low pressure pipelines; Evaluate the reliability of the system under extreme operating conditions (such as 60 ℃ high temperature exposure, -20 ℃ low temperature cold start)
2. System architecture and key nodes The air conditioning system consists of an electric compressor (starting point on the high-pressure side) → condenser → liquid storage dryer → expansion valve → evaporator (passenger compartment refrigeration) → gas-liquid separator → compressor inlet (end point on the low-pressure side) forming a closed loop. The additional circuit includes a battery cooler (coupled with the air conditioning system for battery thermal management) and a PTC heater (auxiliary heat source for heating mode). Key measurement nodes need to cover the compressor outlet, condenser outlet, expansion valve inlet, evaporator outlet, compressor inlet, and battery cooler inlet and outlet to comprehensively capture system operating parameters. Sensor layout and selection. Flow sensor: Coriolis


Current position > Product detail